Factory default

Factory default

Factory default

 In general, resets and Factory Defaults for any OMNEO device can be done with Dante Controller.

 To do a Factory default including or excluding network settings via DANTE Controller:

  1. Double click the unit in Dante Controller
  2. Select the tab “Network Config”
  3. Click “Clear Config”
  4. Check “Reboot”
  5. Uncheck “Keep Network Configuration”
  6. Click “OK” and then “Yes”.


 

 

 

Factory default an ODIN

  1. If applicable, unenroll the unit from DDM.
  2. Enable Factory default of the frame;  do a soft reset or reboot while holding left ENC1 knob.
  3. Go to the Menu Configuration > Advanced > Factory Default.
  4. Ensure that the frame comes back with a default (CAP6-xxxxxx) device name.

 

Factory default a Key Panel

The keypanel can be restored to the factory default configuration by selecting

"Reset Config" from the "Service" menu. If you do this, the changes are not written to flash; to save the changes, you must select Menu | Save Config

 

Factory Default an OMS

  1. Enable Factory default of the frame;  do a soft reset or reboot while holding left ENC1 knob.
  2. Go to the Menu Configuration > Advanced > Factory Default.


Factory default a DBP

Go into the menu "Setup" > "Service" > "Factory default".
 

Factory Default an AP1800

Press and hold the reset button for 10 seconds, release it, then again press and hold for 10 seconds.